MAGLUMI® X3
Save Your Space Without Compromise
Compatible with Small and Medium-sized Hospitals and Labs
Small but strong
- The throughput per unit area is 294 T/h/m²
- Compatible with all MAGLUMI® reagents with perfect compatibility (256 parameters)
Low failure rate and accurate result
- Reaction cup can prevent light pollution, ensuring the accuracy of results
- Integrated packaging of cuvettes avoids the stuck, blockage and scratch
- TEFLON-coated pipetting needle is equipped with independent washing unit to avoid carry-over, ensuring accurate results
Excellent performance
- Advanced design of MAGLUMI® X3 ensures excellent performance, such as the latest intelligent washing technology and bidirectional temperature control measurement
Convenient and efficient
- No-pause loading/unloading of reagents/samples/reaction cups without waiting or interrupting tests
- Intuitive indicator lights make no need to check reagents and consumables frequently
Cost-efficient and intelligent
- Saving consumable cost by not using disposable Tips
- Pipetting needle with three error detection technologies (liquid level /clot /collision), reducing error rate
Outstanding Technologies — X-tech
- Advanced Patented Pipetting Technology *
- A revolutionary pipetting technology with highly accurate volume, ensuring reliable results
- Four kinds of pipetting error detection technologies (liquid level/clot/bubble/collision detection) reduce error rate
- Integrated packaging of disposable filtered Tips ensures no cross-contamination and low failure rate, and avoids aerosol pollution
- One pipetting for multiple tests technology reduces test time and Tips cost
- Accurate Incubation Technology
-
Non-contact mixing
Before incubation, non-contact mixing with different modes ensures sufficient reaction -
Accurate incubation
Single cup design for each test with at least five-sided (X8 is 360°) heating at 37±0.3℃, makes accurate, quick and uniform incubation
- Exclusive Intelligent Washing Technology
Independent washing units for waste liquid needles
In the wash station, four waste liquid
needles are equipped with four
independent washing units to avoid the
carry-over
Magnetic separation washing and non-contact vortex mixing
Magnetic separation washing and non-contact vortex mixing
units, with different mixing modes depending on different
assays, ensure a sufficient washing to reduce the
non-specific binding.
- Stable and Accurate Measuring Chamber
Automatic temperature control in the measuring chamber can keep a stable background value, not affected by
the ambient temperature, ensuring the accuracy of measurement results.
- Pioneer in Optional Wash Liquid Preparation*
Dual-mode wash liquid preparation—Automatic or Manual
- Select Auto mode on the software, connect the X6/X8 to the water purification system, minimize your operational burden
- If water purification system is not available, the wash liquid preparation can be done by manually mixing with pure water
- Flexible Expansion Solutions*
Dual-mode wash liquid preparation—Automatic or Manual
- Same modules can be combined with high throughput and small space occupation
- Capable to integrate with Biossays® C8 (High-throughput Chemistry Analyzer)
- Capable to connect with decapper module
- Capable to link laboratory automation system (TLA/LAS)
Key Technologies
CLIA uses two important technologies, one is the labelling technology which determines the reaction mode, and the other is a separation technology which determines the sensitivity, accuracy and precision of the reagents.
- Labelling Technology
The MAGLUMI® system applies ABEI labels. ABEI is a non-enzyme small molecule with special molecular formula to enhance stability in acid and
alkaline buffer. Using fast Chemiluminescence, ABEI’s chemical reaction with sodium hydroxide (NaOH) and Hyperoxide (H2 O2) finishes the process in 3 seconds.
- Separation Technology
MAGLUMI® uses Magnetic Microbeads. As separation technology, it has been widely used in the field of CLIA. Compared with traditional separation technology, it has the following advantages:
- Shortening the reaction time by enlarging the reaction area of antigens and antibodies.
- Enhancing the sensitivity by better and faster capture of antigens and antibodies.
- Reducing inter or intra-assay discrepancies significantly by mixing the reagents thoroughly in a liquid separation platform.
- Enhancing the accuracy by absorbing antigens and antibodies through chemical reaction.
