MAGLUMI® X8
Super-high Throughput CLIA Solution
Targeted for Large Labs, Chain Labs and Hospitals
Excellent performance
- One of the fastest CLIA analyzers with 600 T/H (Single module)
- Up to 2400 T/H (Four modules combined)
- Compatible with all MAGLUMI® reagents with perfect compatibility (256 parameters)
Saving manpower
- Long walk-away time—2800 tests, saves human labor greatly
- 2912 cuvettes loading in one time with fully-auto cuvette loader, no need to add frequently
Advanced intelligence
- Capable to link Laboratory Automation System (TLA/LAS)
- Capable to integrate with Biossays® C8 (High-throughput Chemistry Analyzer) and decapper module
Considerate design
- Multidimensional indicator lights, real-time monitoring of analyzer's status from a distance
- Dual-mode wash liquid preparation—automatic or manual
- Automatic reagent cover plate and dual temperature mode reduce reagent volatilization and enhance the stability of reagent kits on board
Convenient operation
- User-friendly interface, easy and convenient operation
- No-pause loading and unloading of reagents, samples and consumables without interrupting tests
Outstanding Technologies — X-tech
- Advanced Patented Pipetting Technology *
- A revolutionary pipetting technology with highly accurate volume, ensuring reliable results
- Four kinds of pipetting error detection technologies (liquid level/clot/bubble/collision detection) reduce error rate
- Integrated packaging of disposable filtered Tips ensures no cross-contamination and low failure rate, and avoids aerosol pollution
- One pipetting for multiple tests technology reduces test time and Tips cost
- Accurate Incubation Technology
-
Non-contact mixing
Before incubation, non-contact mixing with different modes ensures sufficient reaction -
Accurate incubation
Single cup design for each test with at least five-sided (X8 is 360°) heating at 37±0.3℃, makes accurate, quick and uniform incubation
- Exclusive Intelligent Washing Technology
Independent washing units for waste liquid needles
In the wash station, four waste liquid
needles are equipped with four
independent washing units to avoid the
carry-over
Magnetic separation washing and non-contact vortex mixing
Magnetic separation washing and non-contact vortex mixing
units, with different mixing modes depending on different
assays, ensure a sufficient washing to reduce the
non-specific binding.
- Stable and Accurate Measuring Chamber
Automatic temperature control in the measuring chamber can keep a stable background value, not affected by
the ambient temperature, ensuring the accuracy of measurement results.
- Pioneer in Optional Wash Liquid Preparation*
Dual-mode wash liquid preparation—Automatic or Manual
- Select Auto mode on the software, connect the X6/X8 to the water purification system, minimize your operational burden
- If water purification system is not available, the wash liquid preparation can be done by manually mixing with pure water
- Flexible Expansion Solutions*
Dual-mode wash liquid preparation—Automatic or Manual
- Same modules can be combined with high throughput and small space occupation
- Capable to integrate with Biossays® C8 (High-throughput Chemistry Analyzer)
- Capable to connect with decapper module
- Capable to link laboratory automation system (TLA/LAS)
Key Technologies
CLIA uses two important technologies, one is the labelling technology which determines the reaction mode, and the other is a separation technology which determines the sensitivity, accuracy and precision of the reagents.
- Labelling Technology
The MAGLUMI® system applies ABEI labels. ABEI is a non-enzyme small molecule with special molecular formula to enhance stability in acid and
alkaline buffer. Using fast Chemiluminescence, ABEI’s chemical reaction with sodium hydroxide (NaOH) and Hyperoxide (H2 O2) finishes the process in 3 seconds.
- Separation Technology
MAGLUMI® uses Magnetic Microbeads. As separation technology, it has been widely used in the field of CLIA. Compared with traditional separation technology, it has the following advantages:
- Shortening the reaction time by enlarging the reaction area of antigens and antibodies.
- Enhancing the sensitivity by better and faster capture of antigens and antibodies.
- Reducing inter or intra-assay discrepancies significantly by mixing the reagents thoroughly in a liquid separation platform.
- Enhancing the accuracy by absorbing antigens and antibodies through chemical reaction.