BC-760 & BC-780
Auto Hematology Analyzer with ESR
KeySpecifications
Principles
WBC(IMG/Neu/Mon/Lym/Eos/Bas), NRBC/RET*, PLT-H/PLT-O*/IPF:
SF Cube^CellAnalysis Technology
^S: Scatter; F: Fluorescence; Cube: 3D analysis
RBC,PLT
Focusing Flow-DC Impedance Method
HGB
Colorimetric method
ESR
Photometric method
Numberofmeasuringparameters(wholeblood):109
Numberofreportableparameters:41
WBCBas#Bas%Neu#Neu%Eos#Eos%Lym#Lym%Mon#
Mon%IMG#IMG%RET%*RET#*RHE*IRF*LFR*MFR*HFR*
RBCHGBMCVMCHMCHCRDW-CVRDW-SDHCTNRBC#
NRBC%PLTPLT-IPLT-HPLT-O*MPVPDWPCTP-LCRP-LCC
IPF ESR
Numberofresearchparameters:68*
Numberofmeasuringparameters(bodyfluid):18
Numberofreportable parameters:7
WBC-BFTC-BF#MN#MN%PMN#PMN%RBC-BF
Numberofresearchparameters:11
Samplevolume
CD(wholeblood): 25ul CD+ESR
(whole blood): 160ul Predilute: 20ul
Data storage capacity
Upto150,000 results including numeric and graphical
information *
Throughput
CD80t/hCDR45t/hCD+ESR40t/h
Analysis Mode
Physical Specifications
Dimensions
840Dx655Wx600Hmm
Weight
≤70.6Kg
Voltage
100V-240V~ (±10%)
Frequency
50Hz/60Hz (±1Hz)
Powerinput
600VA
External output
LANx1, USBx4(Specifications: DC 5V; 500mA;
USB2.0 x 3; USB3.0 x1)
Normal Operating Environment
Ambienttemperature:
10℃~35℃
Relative humidity:
30%~85%
Atmosphericpressure:
70.0kPa ~ 106.0kPa^
^Note : Required altitude for normal operation:-400m~+3000m
Performance
BC-760 & BC-780 Auto Hematology Analyzer with ESR
Above your expectations
- SF Cube fluorescent technology allows reliable counting and differentiation of abnormal samples
Morerefinedandreliable cell
differentiation
3Dfluorescent analysis technology allows
reliable differentiation of immature and other
abnormal cells, such as immature
granulocytes (IMGs), reticulocytes (RETs*), and
immature platelet fraction (IPF).
Morereliable measurements for
low-value samples
The BC-760 & BC-780 3D fluorescence analysis
platform is designed with multiple counting
WBC-3x and PLT-O 5x analysis modes to help
ensure higher reliability for low-value WBC
and PLT samples. In addition, the PLT de
aggregation function can reduce the
cumbersome review work.
Morecomprehensive alarm messages
for abnormalities
The analyzer provides a detailed list of over 40
prompt messages, including WBC message, RBC
message, and PLT message. This allows laboratory
technicians to intuitively and quickly identify
abnormal samples and proceed further with the
samples in a timely manner. This in turn helps to
avoid missed diagnosis of blood disease and false
reports.
BC-760 & BC-780 Auto Hematology Analyzer with ESR
Beyond your expectations
- Limitations of traditional PLT counting
In the traditional impedance method, PLTs are subject to interferences that may lead to falsely high or falsely low results (as shown in the figure). Once an error report is generated, it will directly affect the judgment and decision-making of clinicians. The results reported at the clinical decision level are related to patient safety. Therefore, accurate PLT results are critical in clinical practice.
Optical PLT-H in every CD test
In order to solve the above problem, we have developed a brand new parameter PLT-H.
It combines small PLTs from the conventional impedance method and large PLTs from the optical method. The solution
can resist the interferences in conventional PLT detection without requiring extra reagents.
CD + ESR in one test provide reliable
ESR results with greater ease
The BC-700 series integrates an automatic ESR module in a hematology analyzer. It can also generate both CBC & ESR
results in one test within 1.5 min. In addition, it saves the costs that would otherwise be incurred for the purchase,
maintenance, consumables, and storage space of a separate ESR analyzer. Compared with the traditional Westergren
method, this method performs better in quality traceability, repeatability, speed, safety, and level of automation.